tests/08_seq: Test resetting of SEQ/SQN

the resetting of the SEQ/SQN parameters is currently not tested, we
currently only read out the parameters. Lets test resetting as well.

Change-Id: Ie3e386a79f69cd5e35782f593c3a30e1d2b50afb
Related: OS#3376
This commit is contained in:
Philipp Maier 2018-08-08 12:00:17 +02:00
parent 050231d86c
commit 12f0d25693
2 changed files with 23 additions and 0 deletions

View File

@ -61,3 +61,23 @@ Reading Milenage Sequence parameters...
* Authentication Counter: DISABLED
Done!
sysmoUSIM-SJS1 parameterization tool
Copyright (c)2017 Sysmocom s.f.m.c. GmbH
Initializing smartcard terminal...
Detected Card ICCID: 8988211320300000028
Authenticating...
* Remaining attempts: 3
* Authenticating...
* Authentication successful
* Remaining attempts: 3
Detected Card IMSI: 262423203000002
Resetting MILENAGE Sequence Parameters...
* Initalizing...
* Resetting SQN Configuration to defaults...
Done!

View File

@ -3,3 +3,6 @@
# we can only read them for now, which will of course change once we perform auth against it
$TOOL -a $ADMPIN -s
# test if resetting SQN parameters works
$TOOL -a $ADMPIN -S