[FIX] hw_blackbox_be, hw_scale: don't rely on serial ID to be unique
After plugging in multiple identical serial to USB interfaces, only the last one will be available under /dev/serial/by-id/ because they'll have identical IDs. Instead use /dev/serial/by-path/ which does not have this issue.
This commit is contained in:
parent
acf027ac98
commit
290eb4ea2e
|
@ -37,7 +37,7 @@ class Blackbox(Thread):
|
|||
# request. The first device to give an answer that makes sense
|
||||
# wins.
|
||||
def _find_device_path_by_probing(self):
|
||||
path = "/dev/serial/by-id/"
|
||||
path = "/dev/serial/by-path/"
|
||||
probe_message = self._wrap_low_level_message_around("S000")
|
||||
|
||||
try:
|
||||
|
|
|
@ -29,7 +29,7 @@ class Scale(Thread):
|
|||
self.lock = Lock()
|
||||
self.scalelock = Lock()
|
||||
self.status = {'status':'connecting', 'messages':[]}
|
||||
self.input_dir = '/dev/serial/by-id/'
|
||||
self.input_dir = '/dev/serial/by-path/'
|
||||
self.weight = 0
|
||||
self.weight_info = 'ok'
|
||||
self.device = None
|
||||
|
|